Pumping station Aquapump XL
Duo, GTF1400-S1, 400V
The pumping station without sewage wastewater is equipped with one or two submersible pumps and a backflow preventer. The collection tank made of permanently resistant polymer (PE) has an open pump tank with universal connection options. Quick-release closures enable the integrated components to be removed easily. The KESSEL modular system provides different engineering chamber options as accessories for the further layout. Stainless steel pump removal chains available as accessory for each installation depth - Article number: 680528 = Length 2 m 680529 = Length 3 m 680530 = Length 4 m 680531 = Length 5 m
- Maximum safety
- Flexible installation
- Also handles large quantities of wastewater
Item no. | 8743048 |
---|---|
Price group | 60 |
Pumping station Aquapump XL Duo, GTF1400-S1, 400V
The pumping station without sewage wastewater is equipped with one or two submersible pumps and a backflow preventer. The collection tank made of permanently resistant polymer (PE) has an open pump tank with universal connection options. Quick-release closures enable the integrated components to be removed easily. The KESSEL modular system provides different engineering chamber options as accessories for the further layout. Stainless steel pump removal chains available as accessory for each installation depth - Article number: 680528 = Length 2 m 680529 = Length 3 m 680530 = Length 4 m 680531 = Length 5 m Variant Type of system: duo pump Passage seal for conduit pipe (DN): 63 Passage seal for ventilation pipe (DN): 50 Installation: Wet installation Backwater protection: integrated Pressure pipe connection: horizontal General characteristics Colour: black Standard: EN 12050-2 as well as EN 12050-1 (without ATEX requirements) Type of wastewater: for wastewater with or without sewage (in installation situations without ATEX requirements) Installation situation: floor slab installation Delivery state: Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected) System type: Duo Dimensions Net weight: 192 kg Gross weight: 213 kg Groundwater resistant from lower edge of base section: 3000 mm Width: 1300 mm Height: 1416 mm Length: 1300 mm Tank/drain body Pressure pipe connection (DN): 80 Pressure pipe connection (OD): 90 mm Inlet nominal size (DN): 160 mm Inlet nominal size (DN): 150 Inlet type: 1 Pumping volume: 350 l Pumping device Pump control: GTF 1400 Number of pumps: 2 Weight: 22 kg Connection type: Direct connection Rated current: 6,5 A Length of mains cable for pump: 10 m Self-diagnosis system (SDS): I Insulation class: H Protection class control unit: IP 68 (20m) DSC: integrated Max. temperature (permanent) of conveyed material: 40 °C Max. pumping capacity: 31 m³/h Max. pumping height: 10,5 m Speed: 2900 U/min Power P1: 1,5 kW Power P2: 1,1 kW Operating mode: S1 Type of fuse required (electrical protection): C 16 A Type of pump connection cable: H07RN-F 3G 1.5 mm² Impeller type: Multi-vane impeller Control Motor protection switch: yes Alarm sensor: Level sensor Level measurement instrument: Level sensor Type of level measurement: hydrostatic Protection class probe: IP 54 Mains frequency: 50 Hz Operating voltage: 400 V Connection type: Direct connection Length of mains cable for control unit: 1,4 m Potential-free contact: optional GSM interface: yes USB interface: yes Log book function: yes Multi-line display: yes Battery buffering: yes Self-diagnosis system (SDS): yes Max. permissible switching frequency: Comfort Control unit function: With alarm message Warning equipment version: acoustic and optical signal
Title | Item no. |
---|
Title | Item no. |
---|
Title | Item no. | ||
---|---|---|---|
Basic alarm unit with electronic probe | 20222 | Show | |
Basic alarm unit with optical probe | 20223 | Show | |
Compressor set for air bubbling | 28048 | Show | |
Cable fastener Set for engineering chamber | 28076 | Show | |
TeleControl GSM modem for Comfort control units 230V/400V | 28792 | Show | |
Aerial with magnetic base for TeleControl Modem, Cable 2.5 m | 28793 | Show | |
Extension cable for aerial with magnetic base, L: 2 m | 28794 | Show | |
Connection box for level sensor extension | 28799 | Show | |
Pressure hose Sold by the metre, 6x4 mm 100 | 680071 | Show | |
Seal for intermediate section | 680125 | Show | |
Intermediate section 250 mm, for chamber module LW 1000 | 680370 | Show | |
Intermediate section 500 mm, for chamber module LW 1000 | 680371 | Show | |
Connecting bolt set Set of 10 | 680373 | Show | |
Replacement chain pumping statio. Stainless steel, length 2 m | 680528 | Show | |
Replacement chain pumping statio. Stainless steel, length 3 m | 680529 | Show | |
Chain for KESSEL pumpstations 4m | 680530 | Show | |
Replacement chain, pumping stat. Stainless steel, length 5 m | 680531 | Show | |
Spare part set optical probe | 80888 | Show | |
Sealing set Cable conduit, DN 100 | 85410 | Show | |
Installation set Thermostat, Hygrostat | 97713 | Show | |
Outdoor Cabinet W: 590 mm,for installation control units | 97714 | Show | |
Warning beacon for outdoor cabinet | 97715 | Show | |
Outdoor control cabinet W: 460 mm, for installation control unit | 97716 | Show | |
Outdoor cabinet W: 785 mm, for control unit installation | 97723 | Show | |
Outdoor Cabinet | 97724 | Show |
Title | Item no. |
---|
- Control unit (schaltgeraet): Comfort
- TÜV test mark (pruefzeichen): ID 1111241937
- Installation situation (einbausituation): floor slab installation
- CE marking (ce_kennzeichnung): yes
- Alarm sensor (alarmgeber): Level sensor
- Pump control (pumpe): GTF 1400
- (einbautiefe):
- Impeller type (laufrad_typ): Multi-vane impeller
- Operating voltage (betriebsspannung): 400 V
- ATEX (atex): no