Backwater lifting station Ecolift
DN 150, exposed
The backwater lifting station for faecal and non-faecal wastewater is equipped with one pump and one motor-driven closure system. The pipe cross-section is normally open and the water drains to the sewer via natural fall. Backwater is detected by an optical probe, which causes the motor-driven closure system to close automatically. During the backwater phase, the water drains via a pressure pipe, which carries the wastewater above the backwater level and into the sewer. Connection hole in the drain body for installation in the ground, incl. seal for pressure pipe and cable conduit. The station is controlled by a user-friendly control unit, which is optionally integrated in the building management system via a potential-free contact, or alarm and collective fault messages can be output via a GSM interface.
- Hybrid function: uses the natural fall to the sewer - pump is only used in case of backwater
- Quiet and energy-saving
- Double safety due to backwater flap and pressure loop
Item no. | 21150 |
---|---|
GTIN | 4026092046784 |
Price group | 20 |
Backwater lifting station Ecolift DN 150, exposed
The backwater lifting station for faecal and non-faecal wastewater is equipped with one pump and one motor-driven closure system. The pipe cross-section is normally open and the water drains to the sewer via natural fall. Backwater is detected by an optical probe, which causes the motor-driven closure system to close automatically. During the backwater phase, the water drains via a pressure pipe, which carries the wastewater above the backwater level and into the sewer. Connection hole in the drain body for installation in the ground, incl. seal for pressure pipe and cable conduit. The station is controlled by a user-friendly control unit, which is optionally integrated in the building management system via a potential-free contact, or alarm and collective fault messages can be output via a GSM interface. Variant Emergency closure: yes Passage seal for conduit pipe (DN): 50 Rim width: Control unit Protection class, probe: IP 68 (3m/48h) Motor-driven backwater flaps: 1 General characteristics Colour: black Nominal size (DN): 150 Outer diameter (OD): 160 mm Type of wastewater: with sewage Installation situation: exposed drainage pipe Delivery state: Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected) Inlet max. scoring (DN): Z-53.2-487 Motor type: KSM 140 Protection class (pump): IP 68 (3m/48h) Dimensions Net weight: 20 kg Gross weight: 25,5 kg Groundwater resistant from lower edge of base section: 2000 mm Vertical drop between inlet and outlet: 9 mm Width: 243 mm Height: 405 mm Length: 656 mm Packaging dimension: width: 385 mm Packaging dimension: height: 465 mm Packaging dimension: length: 785 mm Tank/drain body Nominal pressure (PN): 6 Pressure pipe connection (OD): 40 mm System: including spigot and socket Pumping device Pump control: SPZ 1000 Number of pumps: 1 Weight: 10 kg Connection type: coded plug Rated current: 5,2 A Length of mains cable for pump: 5 m Self-diagnosis system (SDS): I Insulation class: F Cos phi - power factor: 0,97 Protection class control unit: IP 68 (3m/48h) DSC: integrated Max. temperature (permanent) of conveyed material: 40 °C Max. pumping capacity: 11,5 m³/h Max. pumping height: 10 m Speed: 2800 U/min Power P1: 1,2 kW Power P2: 0,69 kW Operating mode: S3 - 50 % Type of fuse required (electrical protection): C 16 A Type of pump connection cable: H07RN-F 3G 1.5 mm² Impeller type: Macerator Control Standby power: 5 W Alarm sensor: optical probe Level measurement instrument: optical probe Type of level measurement: optical Protection class probe: IP 54 Operating voltage: 230 V Connection type: coded plug Length of mains cable for control unit: 1,4 m Potential-free contact: yes GSM interface: no USB interface: no Log book function: yes Multi-line display: yes Battery buffering: yes Self-diagnosis system (SDS): yes Max. permissible switching frequency: Comfort
Title | Item no. |
---|
Title | Item no. |
---|
Title | Item no. | ||
---|---|---|---|
Remote signal generator 20 m cable, 2x0.75 q | 20162 | Show | |
Pressure pipe set 5 m pressure hose, DA 40 mm | 28040 | Show | |
Clearance code for potential-free contact | 80077 | Show | |
10 m probe cable extension set | 80889 | Show | |
Cable extension set for motor 10 m | 80890 | Show | |
Cable prolongation set for pump 10 m | 80891 | Show |
Title | Item no. | ||
---|---|---|---|
Cover Ecolift outlet side | 21056 | Show | |
Pump cover inlet side | 28052 | Show | |
Vent for Pumpfix Premium | 28060 | Show | |
Active carbon filter | 28061 | Show | |
Control unit Comfort 230V, from 01/2011 | 28071 | Show | |
Replacement pump AqualiftF/Pumpfix F | 28351 | Show | |
One-handed closure for backflow preventer | 680018 | Show | |
Battery 9 V block | 680034 | Show | |
Flap holder for motor-driven and mechanical flap | 680101 | Show | |
Pressure pipe connection Ecolift, installation with exposed pipe | 680102 | Show | |
Gasket set (Pumpfix, Ecolift) | 70319 | Show | |
Motor-driven backwater flap Premium | 80038 | Show | |
Insert part f. motor-driven flap Premium | 80039 | Show | |
Staufix FKA drive motor (KSM 140) 5m | 80076 | Show | |
Spare part set optical probe | 80888 | Show | |
Adapter set optical probe | 80892 | Show | |
Staufix Premium Spigot DN 150 | 83083 | Show | |
Staufix Premium Socket DN 150 | 83087 | Show |
Manuals | |
---|---|
CAD Data | |
Approval | |
Test Reports and Certificates | |
Declaration of Performance |
- Nominal size (DN) (nennweite): 150
- Control unit (schaltgeraet): Comfort
- TÜV test mark (pruefzeichen): ID 1111241795
- Installation situation (einbausituation): exposed drainage pipe
- Type of wastewater (abwasserart_de): with sewage
- Length (laenge): 656 mm
- Width (breite): 243 mm